Whatever your electrochemistry needs may be - pH, ORP, conductivity, Total Dissolved Solids, various ions - and wherever your work takes you, lab or field, Lab Procurement Services can provide the equipment you need at a competitive price. Please see our selection of Electrochemistry Meters, Probes and Sensors, as well as Electrochemistry Parts.
Also be sure to check out pH Buffers, Beakers, and Reusable Glassware for other essential products you may need to complete your purchase.
Feel free to give us a call if you ned assistance with product selection, pricing, or availability!
Before choosing a meter or electrode, decide where it will be used (benchtop, portable or pocket tester), which parameters you need on one instrument, and whether you need GLP features such as data logging. Then match the electrode to the sample. The product range here includes electrodes for meats, soil, viscous liquids, pure or low ionic strength water, high-temperature and caustic solutions, micro-volume samples, emulsions and wastewater. Check the electrode body (glass or plastic), the connector (such as BNC) and temperature compensation, and confirm that a replacement probe is listed for your meter model. Turbidity meters are listed by method, such as EPA 180.1 or ISO 7027.
Laboratory electrochemistry equipment measures the electrical properties of solutions. Common instruments are pH and ORP meters, conductivity and TDS meters, dissolved oxygen meters, ion-selective meters for ions such as fluoride, and multiparameter meters that combine several measurements. Each meter works with a matching electrode or sensor, and most need calibration solutions such as pH buffers or conductivity standards.
Some pocket testers take a replaceable probe, so you can replace the sensor without replacing the meter. For example, the PH60S-DE is listed as a replacement probe for the ZenTest PH60S-Z Smart Spear pocket tester. Check that the replacement is named for your exact model before ordering, because probes from different tester models are usually not interchangeable.
Pure and low ionic strength water conducts very little current, so a general-purpose electrode can give slow, drifting or noisy readings. Electrodes designed for these samples use reference junctions that keep the measurement stable. Readings in pure water are also easily affected by carbon dioxide absorbed from the air, so measure promptly and follow the electrode's instructions.
Most labs calibrate at the start of each day or measurement session, using at least two fresh buffers that bracket the expected sample pH, and recalibrate if readings drift or the electrode is changed. Requirements under a quality system may be stricter. Keep the electrode stored in the solution the manufacturer recommends so it responds quickly.
Shop by type: Electrochemistry Meters · Electrodes and Sensors · Electrochemistry Parts