Manufacturer: Apera Instruments
Advanced, Intuitive Interface — Plain-language menus and graphic screen prompts eliminate the need for extensive manual reading or training. Multi-language support includes English, German, Spanish, and Chinese.
GLP Data Management — Manual/automatic data logger with 200 sets of GLP-compliant data storage containing calibration data and time stamps. Export data via USB to PC.
Apera TestBench Included — Integrated workstation with a flexible electrode holder, intelligent magnetic stirrer, and buffer organizers — dramatically streamlines calibration and measurement workflows.
LabSen® 211 pH Electrode — Features a low-impedance glass membrane and long-life reference system. Supports 0–100°C ATC via the MP500 temperature probe. Compatible with TRIS buffers.
Flexible Calibration Options — 1 to 3 point auto. calibration recognizing standard buffers (1.68 / 4.00 / 7.00 / 10.01 / 12.45) or user-defined standards. Automatic electrode slope display and calibration self-diagnosis.
Broad Compatibility — Standard BNC pH connector & RCA temperature connector (NTC 30KΩ). Compatible with all Swiss LabSen electrodes for specialized samples.
| Parameter Menu | Options | Factory Default |
|---|---|---|
| 1.0 pH | ||
| 1.1 pH Buffer Selection | CH / USA / NIST / User | USA |
| 1.2 Resolution | 0.01 / 0.1 | 0.01 |
| 1.3 Last Calibration Data | View | — |
| 1.4 Restore Factory Default | Yes / No | No |
| 3.0 Configuration | ||
| 3.1 Reading with HOLD | On / Off | — |
| 3.2 Auto Timing Data Log | Manual / Automatically | Manual |
| 3.3 Temperature Unit | °C / °F | — |
| 3.4 Delete Saved Data | Yes / No | No |
| 3.5 Language Selection | English / Deutsch / Español / Chinese | English |
| 3.6 Date Format | Y-M-D | — |
| 3.7 Time Format | 24-hour / 12-hour | — |
| 3.8 Date Setting | YYYY-MM-DD | — |
| 3.9 Time Setting | HH:MM:SS | — |
| Item | Quantity |
|---|---|
| PH950 pH/Conductivity Meter | 1 |
| 606 Test-Bench (with flexible electrode holder) | 1 |
| LabSen 211 Glass pH Combination Electrode | 1 |
| MP500 Temperature Electrode | 1 |
| pH Standard Buffers (4.00 / 7.00 / 10.01 pH, 50mL each) | 3 |
| Stirrer Power Cable | 1 |
| USB Cable | 1 |
| PC-Link Flash Drive | 1 |
| 9V Adapter | 1 |
| Calibration Vials | 3 |
| L200 Stir Beads | 3 |
| User Manual | 1 |
| pH | Measuring Range | (0.00 ~ 14.00)pH |
| Resolution | 0.1/0.01 pH | |
| Accuracy | ±0.01 pH ±1 digit | |
| Temperature Compensation Range | (0 to 100)°C (Auto. or Manual) | |
| Calibration point | 1 to 3 points | |
| mV | Measuring Range | ±2000mV |
| Resolution | 1mV | |
| Accuracy | ±0.1% FS ±1 digit | |
| Resolution | 0.01/0.1/1μS/cm 0.01/0.1 mS/cm | |
| Accuracy | ±1.0% FS ±1 digit | |
| Temperature Compensation Range | (0 to 50)°C (Auto. or Manual) | |
| Cell constant | 0.1 / 1 / 10 cm-1 | |
| Temp. | Measuring Range | 0~100? |
| Thermistor | 30KΩ NTC | |
| Resolution | 0.1? | |
| Accuracy | ±0.5°C±1 digit |
| Data Storage | 100 sets |
| Storage Content | Number, measuring value and temperature value |
| Connector | BNC for pH and ORP; RCA for temperature |
| Power | Input: 120V AC 60Hz; Output: DC9V/600mA, 2.7VA |
| Dimension & Weight | Meter:(195×215×100 )mm / 0.9kg |
| What's in the box? | PH950 Meter, TestBench, LabSen®211 pH electrode, MP500 temperature probe, 9V power adapter, flexible electrode holder, 50ml of pH buffers (4.00, 7.00, 10.01), instruction manual |
Manufacturer Part Number/SKU: PH950-EA