Manufacturer: Apera Instruments
Advanced, Intuitive Interface — Plain-language menus and graphic screen prompts eliminate the need for extensive manual reading or training. Multi-language support includes English, German, Spanish, and Chinese.
Dual-Channel Simultaneous Measurement — Measures pH/mV(ORP) and conductivity/TDS/salinity at the same time for maximum efficiency.
GLP Data Management — Manual/automatic data logger with 200 sets of GLP-compliant data storage containing calibration data and time stamps. Export data via USB to PC.
Flexible Calibration Options — 1 to 3 point auto. calibration recognizing standard buffers (1.68 / 4.00 / 7.00 / 10.01 / 12.45) or user-defined standards. Automatic electrode slope display and calibration self-diagnosis.
Broad Compatibility — Standard BNC pH connector & RCA temperature connector (NTC 30KΩ). Compatible with all Swiss LabSen electrodes for specialized samples.
2301T-F Conductivity Electrode — firm platinum black sensor delivers high-accuracy measurements from 0 to 200 mS/cm at ±1% F.S accuracy.
Flexible Conductivity Calibration — 1 to 4 point auto. calibration with standard solutions (84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm) or user-defined standards.
Quick Parameter Switching — One-tap conversion among conductivity, TDS, and salinity.
Multiple Salinity Modes — Select from general salinity, saltwater salinity, or NaCl salinity.
Broad Compatibility — Standard BNC conductivity connector; compatible with 2310T-F (up to 2000 mS/cm) and DJS-0.1-F for high-purity water. Uses RCA temperature connector (NTC 30KΩ).
| Parameter Menu | Options | Factory Default |
|---|---|---|
| 1.0 pH | ||
| 1.1 pH Buffer Selection | CH / USA / NIST / User | USA |
| 1.2 Resolution | 0.01 / 0.1 | 0.01 |
| 1.3 Last Calibration Data | View | — |
| 1.4 Restore Factory Default | Yes / No | No |
| 2.0 Conductivity / TDS | ||
| 2.1 Cell Constant | 10 / 1.0 / 0.1 | 1.0 |
| 2.2 CAL Solution Selection | Standard / CN / User | Standard |
| 2.3 Last Calibration Data | View | — |
| 2.4 Reference Temperature | 15–30 °C | 25 °C |
| 2.5 Temp Compensation Factor | 0.00–10.00% | 2.0% |
| 2.6 TDS Factor | 0.40–1.00 | 0.71 |
| 2.7 Restore Factory Default | Yes / No | No |
| 3.0 Configuration | ||
| 3.1 Reading with HOLD | On / Off | — |
| 3.2 Auto Timing Data Log | Manual / Automatically | Manual |
| 3.3 Temperature Unit | °C / °F | — |
| 3.4 Delete Saved Data | Yes / No | No |
| 3.5 Language Selection | English / Deutsch / Español / Chinese | — |
| 3.6 Date Format | Y-M-D | — |
| 3.7 Time Format | 24-hour / 12-hour | — |
| 3.8 Date Setting | YYYY-MM-DD | — |
| 3.9 Time Setting | HH:MM:SS | — |
| Item | Quantity |
|---|---|
| PC910 pH/Conductivity Meter | 1 |
| 602 Flexible Electrode Holder | 1 |
| LabSen 211 Glass pH Combination Electrode | 1 |
| MP500 Temperature Electrode | 1 |
| 2301T-F Conductivity Electrode (ATC, K=1.0) | 1 |
| pH Standard Buffers (4.00 / 7.00 / 10.01 pH, 50mL each) | 3 |
| Conductivity Calibration Solutions (84 µS / 1413 µS / 12.88 mS, 50mL each) | 3 |
| USB Cable | 1 |
| PC-Link 9500 Flash Drive | 1 |
| 9V Adapter | 1 |
| User Manual | 1 |
| Parameter | Specification |
|---|---|
| pH Measurement | |
| Measuring Range | 0.00 – 14.00 pH |
| Resolution | 0.1 / 0.01 pH |
| Accuracy | ±0.01 pH ±1 digit |
| Temp. Compensation Range | 32 – 212°F (0 – 100°C), Auto or Manual |
| Calibration Points | 1–3 points |
| mV Measurement | |
| Measuring Range | ±2000 mV |
| Resolution | 1 mV |
| Accuracy | ±0.1% F.S. ±1 digit |
| Conductivity / TDS / Salinity | |
| Conductivity Measuring Range | 0 – 200 mS/cm (auto range): (0 – 19.99) µS/cm (20.0 – 199.9) µS/cm (200 – 1999) µS/cm (2.00 – 19.99) mS/cm (20.0 – 199.9) mS/cm |
| TDS Measuring Range | 0 – 100 g/L |
| Salinity Measuring Range | 0 – 100 ppt |
| Resolution | 0.01 / 0.1 / 1 µS/cm; 0.01 / 0.1 mS/cm |
| Accuracy | ±1.0% F.S. ±1 digit |
| Temp. Compensation Range | 32 – 122°F (0 – 50°C), Auto or Manual |
| Cell Constant | 0.1 / 1 / 10 cm?¹ |
| Temperature Measurement | |
| Measuring Range | 32 – 212°F (0 – 100°C) |
| Resolution | 0.1°F (0.1°C) |
| Accuracy | ±0.9°F (±0.5°C) ±1 digit |
| Other Technical Parameters | |
| Data Storage | 200 sets |
| Storage Contents | Numberings, date, time, measurement value, temperature |
| Power Supply | DC 9V / 600 mA |
| Dimensions & Weight | 195 × 215 × 100 mm / 0.9 kg |
Manufacturer Part Number/SKU: PC910-EA
Tags: Apera Instruments