Labexact Sterile MCE Syringe Filters, 0.22(um), 13(mm), 100 pack

Labexact Sterile MCE Syringe Filters, 0.22(um), 13(mm), 100 pack

Labexact Sterile MCE Syringe Filters, 0.22(um), 25(mm), 100 pack

Labexact Sterile MCE Syringe Filters, 0.22(um), 25(mm), 100 pack

Labexact Sterile MCE Syringe Filters, 0.45(um), 13(mm), 100 pack

was $236.33 Special Price $176.51
Labexact Sterile MCE Syringe Filters, 0.45(um), 13(mm), 100 pack (100 per PK )

Manufacturer: I. W. Tremont

SKU
LEIWT-ES10106-PK
Labexact Sterile MCE Syringe Filters, 0.45(um), 13(mm), 100 pack is available to buy in increments of 1

Product Details

Download Details and Specifications

 

Specialty Syringe Filters

HPLC Certified

High quality and cost effective syringe filters are
available in a broad range of membrane materials
with sterile and non-sterile packaging options.

Features

  • Disposable
  • Luer-Lok™ and pressure fitting
  • Ultrasonically bonded for reliability
  • Filter media type clearly inscribed on barrel
  • Excellent unit-to-unit and lot-to-lot reproducibility and consistency
  • High purity virgin polypropylene housing, no dyes or pigments added
  • Every unit type is available as an individually wrapped gamma sterilized pack
  • Unique concentric funnel shaped barrel increases volume and decreases back pressure

 

Product Selection Guide

Evaluate sample:

  • Determine chemical compatibility, volume and need for prefiltration

Determine level of prefiltration necessary:

  • In filter unit vs. prefilter unit in series for coarse precipitants.

Choose filter media type:

  • Aqueous: Nylon, MCE, CA
  • Non-polar: Nylon, PTFE, PVDF
  • Protein: PVDF, PES

Choose barrel diameter:

  • 10 mL: 13 mm diameter
  • 100 mL: 25 mm diameter

Choose initial or secondary retention target:

  • 0.45 µm or 0.20 µm

Filter Material Specs

Filtration Media / Application Guide (hydrophobic or hydrophilic)
Glass microfiber filter media - prefilter versions available in all variations except MultiDensity which includes prefilter

  • This membrane is recommended for all filtrations in aqueous or polar media, bacteria filtration
  • Ideal when maximum protein recovery in filtrate is crucial
  • Used for filtration and inspection of gas, oil and alcohol particulate and bacteria
  • Combined with glass microfiber prefilter, ideal for tissue culture media and sensitive biological samples
  • Sample filtration - prefilter increases yield
  • Very low binding capacity for proteins.
  • Material is nitrate-free making it suitable for groundwater & EPA ASTM’s.
  • For filtration under sterile conditions
  • Filtration and clarification of biological fluids, sterilization of media additives and serum
  • Sample preparation of aqueous solutions
  • For applications requiring maximum sample recovery
  • Sample preparation of protein-based HPLC solutions
  • Designed to sterilize and remove particulates from even the most viscous proteinaceous samples
  • Filtration of tissues culture media with glass fiber prefilter
  • Hydrophilic material; it is recommended for filtration of aqueous or organic/aqueous medium polar liquids.
  • Commonly used for general laboratory filtration and filtration of HPLC and GC samples prior to injection
  • Filtration of aqueous and organic-aqueous polar medium liquids
  • Dissolution sample analysis
  • Suitable for use with high pH samples
  • Since it binds proteins it is NOT suitable for protein recovery applications
  • With microfiber prefilter higher absorption capacity for contamination
  • High filtration flow rates
  • An inherently low affinity for proteins.
  • Low extractables
  • Introduction of additives into tissue culture vessel.
  • Certified for Ion Chromatography
  • Final filtration of bacteriophage and infusion solutions
  • Tissue culture, proteins, buffer and nucleic acids filtration
  • Ideal for applications requiring maximum sample recovery
  • Filter hybridization solutions and probe to reduce backgrounds
  • Food, beverages and ultra pure water final filtration
  • Sterile product individually blister packed

Polyvinylidene difluoride (PVDF) - Hydrophobic

  • This membrane features a stability and hydrophobic interactions similar to PTFE.
  • Recommended especially for filtration of water-soluble oligomers and polymers, e.g. protein solutions.
  • Can also be used for the filtration of hydrophobic substances in different organic solvents.
  • PTFE membranes are inherently hydrophobic; they are ideal for the filtration of nonpolar liquids and gases.
  • Very resistant to solvents as well as acids or bases.
  • Can be made more hydrophilic by flushing with alcohol, followed by water
  • Used for filtering and de-gassing chromatography solvents
  • Permits optimal utilization of small sample volumes
  • Excellent chemical compatibility for filtering harsh chemicals that destroy other membrane materials
  • Moisture barrier for venting applications and vacuum pump line protection
  • Ideal for aerosol sampling
  • Filter viscous organic based HPLC samples
  • After pre-wetting with alcohol, may be used for fine particle removal of aqueous and mild organic solutions in Ion Chromatography
  • For viscose solutions or for turbid liquids
  • Glass microfiber prefilter raises absorption capacity and loading
  • Ideal for use as a prefilter in series with other syringe filters
  • Glass microfiber filter media enclosed in this series is binderless 1.0µm retention
  • Reduces clogging of the membrane, so ideal as a prefilter to increase throughput and flow rate
  • Ideal for dissolution testing and general filtration
  • Applicable to all membrane types, allowing higher flow rates
  • Good compatibility with strong acids, bases and organic solvents
  • Similar in composition to I.W. Tremont binderless borosilicate glass microfiber media available as disks and sheets

Polypropylene (PP)

  • The polypropylene membrane is resistant to many organic solvents and slightly hydrophobic
  • Useful for aqueous and organic solutions
  • Low non-specific protein binding

MultiDensity Nano Glass Micro Fiber

  • Multi Density Glass Microfiber with several layers of density that speeds and optimizes filtration
  • Bridges the gap between macro and micro analytical filtration
  • Media includes multi pre-filtration stages and final retention stage down to 0.5um
  • Built-in prefilter captures particulate from >300μm and binds typically difficult to filter substances without clogging such as lipids (natural oils and waxes), petrochemical oils, tars, cellular matter and proteins.

Nano Glass Micro Fiber A83

  • Nano-scale glass microfiber has the loading capacity of a binderless glass microfiber filter with the tightly regulated pore size of a microfiltration membrane
  • This specialty grade has a particle retention of 0.5µm
  • A83 has >20x loading capacity of an equivalent porosity MCE or CN membrane and >15x the flow rate
  • Chemically inert, pure binderless borosilicate glass with no sizing additives or other surfactants
  • Low background noise in LC/GC/MS and very low extractables in presence of aggressive solvents
  • Smooth sheath of the glass fiber allows tight consolidation into a highly retentive filter mat
  • High protein affinity and highly washable for separation recovery
  • Chemically stable in presence of all acids with exception of hydrofluoric acid

Fibrous Cellulose Acetate

  • Fibrous Cellulose Acetate depth filter media demonstrates a high surface area to mass ratio and natural high loading capacity
  • Unique fibrous material demonstrates similar advantages as its Cellulose Acetate surface membrane counterparts such as surface bonding, high purity and biocompatibility
  • Fibrous media has an inherent charge that initially has high protein binding but upon loading, releases easily and completely for high recovery rates

Tri-Layer PP/GF Prefilters with Nylon, PVDF or PTFE Membrane

  • A tri-layer filter with both a glass microfiber and polypropylene prefilter that raises absorption capacity and loading of a choice of Nylon PTFE or PVDF membrane
  • Designed for viscous solutions or for turbid liquids

 

Technical Specifications:
Typical physical characteristics:
 13mm diameter barrel25mm diameter barrel
   
Surface area (cm²)0.653.90
Sample volume (ml)<15<105
Maximum pressure (bar)4590
Hold up volume (µl)8.528.5
Connector inletLuer-Lok™Luer-Lok™
Connector outletluer-slip (non-barb)luer-slip (non-barb)

Syringe Filters Products

Material Classifications>

 

Polyamide/Nylon (PA) – Hydrophilic

Polytetrafluoroethylene (PTFE) – Hydrophilic or Hydrophobic

Polyvinylidene difluoride (PVDF) – Hydrophobic

Polyethersulfone (PES) – Hydrophilic

Cellulose Acetate (CA) – Hydrophilic

Mixed Cellulose Esters (MCE)-Hydrophilic

Prefilters, Glass Microfiber

Polypropylene (PP)

MultiDensity Nano Glass Microfiber

Nano Microfiber

Cellulose Acetate Fibrous

Tri-Layer PP/GF with Nylon, PVDF, PTFE

 

 

Product Catalog #Description
IWT-ES10000Nonsterile Nylon Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10001Nonsterile Nylon Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10002Nonsterile Nylon Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10003Nonsterile Nylon Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10004Nonsterile Nylon Syringe Filters, 0.22(μm), 33(mm), 100 pack
IWT-ES10005Nonsterile Nylon Syringe Filters, 0.45(μm), 33(mm), 100 pack
IWT-ES10007Sterile Nylon Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10008Sterile Nylon Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10009Sterile Nylon Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10010Sterile Nylon Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10011Sterile Nylon Syringe Filters, 0.22(μm), 33(mm), 100 pack
IWT-ES10012Sterile Nylon Syringe Filters, 0.45(μm), 33(mm), 100 pack
IWT-ES10180Nonsterile Nylon Syringe Filters, 0.22(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10181Nonsterile Nylon Syringe Filters, 0.45(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10182Nonsterile Nylon Syringe Filters, 0.22(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10183Nonsterile Nylon Syringe Filters, 0.45(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10185Sterile Nylon Syringe Filters, 0.22(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10186Sterile Nylon Syringe Filters, 0.45(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10187Sterile Nylon Syringe Filters, 0.22(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10188Sterile Nylon Syringe Filters, 0.45(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10232Nonsterile Nylon Syringe Filters, 0.22(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10233Nonsterile Nylon Syringe Filters, 0.45(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10234Nonsterile Nylon Syringe Filters, 0.22(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10235Nonsterile Nylon Syringe Filters, 0.45(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10237Sterile Nylon Syringe Filters, 0.22(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10238Sterile Nylon Syringe Filters, 0.45(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10239Sterile Nylon Syringe Filters, 0.22(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10240Sterile Nylon Syringe Filters, 0.45(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10300Nonsterile Nylon Syringe Filters, 0.22 (µm), 17 (mm), 100 pack
IWT-ES10301Nonsterile Nylon Syringe Filters, 0.45 (µm), 17 (mm), 100 pack
IWT-ES10302Nonsterile Nylon Syringe Filters, 0.22 (µm), 30 (mm), 100 pack
IWT-ES10303Nonsterile Nylon Syringe Filters, 0.45 (µm), 30 (mm), 100 pack
IWT-ES10304Sterile Nylon Syringe Filters, 0.22 (µm), 30 (mm), 100 pack
IWT-ES-10601Nonsterile Nylon syringe filter, 4mm diameter, 0.22(µm), membrane, 200pk
IWT-ES-10602Nonsterile Nylon syringe filter, 4mm diameter, 0.45(µm), membrane, 200pk
IWT-ES10017Nonsterile PTFE Syringe Filters, 0.22(μm), 13(mm), Hydrophobic, 100 pack
IWT-ES10018Nonsterile PTFE Syringe Filters, 0.45(μm), 13(mm), Hydrophobic, 100 pack
IWT-ES10019Nonsterile PTFE Syringe Filters, 0.22(μm), 25(mm), Hydrophobic, 100 pack
IWT-ES10020Nonsterile PTFE Syringe Filters, 0.45(μm), 25(mm), Hydrophobic, 100 pack
IWT-ES10024Sterile PTFE Syringe Filters, 0.22(μm), 13(mm), Hydrophobic, 100 pack
IWT-ES10025Sterile PTFE Syringe Filters, 0.45(μm), 13(mm), Hydrophobic, 100 pack
IWT-ES10026Sterile PTFE Syringe Filters, 0.22(μm), 25(mm), Hydrophobic, 100 pack
IWT-ES10027Sterile PTFE Syringe Filters, 0.45(μm), 25(mm), Hydrophobic, 100 pack
IWT-ES10603Nonsterile PTFE syringe filter, 0.22(μm), 4(mm) ,Hydrophobic, 200pk
IWT-ES10604Nonsterile PTFE syringe filter, 0.45(μm), 4(mm) ,Hydrophobic, 200pk
IWT-ES10034Nonsterile PTFE Syringe Filters, 0.22(μm), 13(mm), Hydrophilic, 100 pack
IWT-ES10035Nonsterile PTFE Syringe Filters, 0.45(μm), 13(mm), Hydrophilic, 100 pack
IWT-ES10036Nonsterile PTFE Syringe Filters, 0.22(μm), 25(mm), Hydrophilic, 100 pack
IWT-ES10037Nonsterile PTFE Syringe Filters, 0.45(μm), 25(mm), Hydrophilic, 100 pack
IWT-ES10039Sterile PTFE Syringe Filters, 0.22(μm), 13(mm), Hydrophilic, 100 pack
IWT-ES10040Sterile PTFE Syringe Filters, 0.45(μm), 13(mm), Hydrophilic, 100 pack
IWT-ES10041Sterile PTFE Syringe Filters, 0.22(μm), 25(mm), Hydrophilic, 100 pack
IWT-ES10042Sterile PTFE Syringe Filters, 0.45(μm), 25(mm), Hydrophilic, 100 pack
IWT-ES10605Nonsterile PTFE syringe filter, 0.22(μm), 4(mm) ,Hydrophilic, 200pk
IWT-ES10606Nonsterile PTFE syringe filter, 0.45(μm), 4(mm) ,Hydrophilic, 200pk
IWT-ES10141Nonsterile PTFE Syringe Filters, 0.22(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10142Nonsterile PTFE Syringe Filters, 0.45(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10143Nonsterile PTFE Syringe Filters, 0.22(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10144Nonsterile PTFE Syringe Filters, 0.45(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10146Sterile PTFE Syringe Filters, 0.22(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10147Sterile PTFE Syringe Filters, 0.45(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10148Sterile PTFE Syringe Filters, 0.22(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10149Sterile PTFE Syringe Filters, 0.45(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10193Nonsterile PTFE Syringe Filters, 0.22(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10194Nonsterile PTFE Syringe Filters, 0.45(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10195Nonsterile PTFE Syringe Filters, 0.22(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10196Nonsterile PTFE Syringe Filters, 0.45(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10198Sterile PTFE Syringe Filters, 0.22(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10199Sterile PTFE Syringe Filters, 0.45(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10200Sterile PTFE Syringe Filters, 0.22(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10201Sterile PTFE Syringe Filters, 0.45(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10320Nonsterile PTFE Syringe Filters, 0.22 (µm), 17 (mm), 100 pack
IWT-ES10321Nonsterile PTFE Syringe Filters, 0.45 (µm), 17 (mm), 100 pack
IWT-ES10322Nonsterile PTFE Syringe Filters, 0.22 (µm), 30 (mm), 100 pack
IWT-ES10323Nonsterile PTFE Syringe Filters, 0.45 (µm), 30 (mm), 100 pack
IWT-ES10047Nonsterile PVDF Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10048Nonsterile PVDF Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10049Nonsterile PVDF Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10050Nonsterile PVDF Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10054Sterile PVDF Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10055Sterile PVDF Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10056Sterile PVDF Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10057Sterile PVDF Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10167Nonsterile PVDF Syringe Filters, 0.22(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10168Nonsterile PVDF Syringe Filters, 0.45(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10169Nonsterile PVDF Syringe Filters, 0.22(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10170Nonsterile PVDF Syringe Filters, 0.45(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10172Sterile PVDF Syringe Filters, 0.22(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10173Sterile PVDF Syringe Filters, 0.45(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10174Sterile PVDF Syringe Filters, 0.22(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10175Sterile PVDF Syringe Filters, 0.45(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10219Nonsterile PVDF Syringe Filters, 0.22(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10220Nonsterile PVDF Syringe Filters, 0.45(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10221Nonsterile PVDF Syringe Filters, 0.22(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10222Nonsterile PVDF Syringe Filters, 0.45(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10224Sterile PVDF Syringe Filters, 0.22(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10225Sterile PVDF Syringe Filters, 0.45(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10226Sterile PVDF Syringe Filters, 0.22(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10227Sterile PVDF Syringe Filters, 0.45(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10330Nonsterile PVDF Syringe Filters, 0.22 (µm), 17 (mm), 100 pack
IWT-ES10331Nonsterile PVDF Syringe Filters, 0.45 (µm), 17 (mm), 100 pack
IWT-ES10332Nonsterile PVDF Syringe Filters, 0.22 (µm), 30 (mm), 100 pack
IWT-ES10333Nonsterile PVDF Syringe Filters, 0.45 (µm), 30 (mm), 100 pack
IWT-ES-10607Nonsterile PVDF Syringe Filters syringe filter,0.22(µm), 4 (mm) , 200PK
IWT-ES-10608Nonsterile PVDF Syringe Filters, syringe filter,, 0.45(µm), 4 (mm) , 200PK
IWT-ES10064Nonsterile PES Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10065Nonsterile PES Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10066Nonsterile PES Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10067Nonsterile PES Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10071Sterile PES Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10072Sterile PES Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10073Sterile PES Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10074Sterile PES Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10154Nonsterile PES Syringe Filters, 0.22(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10155Nonsterile PES Syringe Filters, 0.45(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10156Nonsterile PES Syringe Filters, 0.22(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10157Nonsterile PES Syringe Filters, 0.45(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10159Sterile PES Syringe Filters, 0.22(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10160Sterile PES Syringe Filters, 0.45(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10161Sterile PES Syringe Filters, 0.22(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10162Sterile PES Syringe Filters, 0.45(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10206Nonsterile PES Syringe Filters, 0.22(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10207Nonsterile PES Syringe Filters, 0.45(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10208Nonsterile PES Syringe Filters, 0.22(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10209Nonsterile PES Syringe Filters, 0.45(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10211Sterile PES Syringe Filters, 0.22(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10212Sterile PES Syringe Filters, 0.45(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10213Sterile PES Syringe Filters, 0.22(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10214Sterile PES Syringe Filters, 0.45(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10310Nonsterile PES Syringe Filters, 0.22 (µm), 17 (mm), 100 pack
IWT-ES10311Nonsterile PES Syringe Filters, 0.45 (µm), 17 (mm), 100 pack
IWT-ES10312Nonsterile PES Syringe Filters, 0.22 (µm), 30 (mm), 100 pack
IWT-ES10313Nonsterile PES Syringe Filters, 0.45 (µm), 30 (mm), 100 pack
IWT-ES10609Nonsterile PES syringe filter,0.22(µm), 4 (mm), membrane, 200PK
IWT-ES10610Nonsterile PES syringe filter, 0.45(µm),4 (mm), membrane, 200PK
IWT-ES10081Nonsterile CA Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10082Nonsterile CA Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10083Nonsterile CA Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10084Nonsterile CA Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10088Sterile CA Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10089Sterile CA Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10090Sterile CA Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10091Sterile CA Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10611Nonsterile CA syringe filter, 4mm diameter, 0.22micron, membrane, 200PK
IWT-ES10612Nonsterile CA syringe filter, 4mm diameter, 0.45micron, membrane, 200PK
IWT-ES10098Nonsterile MCE Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10099Nonsterile MCE Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10100Nonsterile MCE Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10101Nonsterile MCE Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10105Sterile MCE Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10106Sterile MCE Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10107Sterile MCE Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10108Sterile MCE Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10115Nonsterile GF Syringe Filters, 0.70(μm), 13(mm), 100 pack
IWT-ES10116Nonsterile GF Syringe Filters, 1.00(μm), 13(mm), 100 pack
IWT-ES10117Nonsterile GF Syringe Filters, 0.70(μm), 25(mm), 100 pack
IWT-ES10118Nonsterile GF Syringe Filters, 1.00(μm), 25(mm), 100 pack
IWT-ES10120Sterile GF Syringe Filters, 0.70(μm), 13(mm), 100 pack
IWT-ES10121Sterile GF Syringe Filters, 1.00(μm), 13(mm), 100 pack
IWT-ES10122Sterile GF Syringe Filters, 0.70(μm), 25(mm), 100 pack
IWT-ES10123Sterile GF Syringe Filters, 1.00(μm), 25(mm), 100 pack
IWT-ES10128Nonsterile PP Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10129Nonsterile PP Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10130Nonsterile PP Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10131Nonsterile PP Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10133Sterile PP Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10134Sterile PP Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10135Sterile PP Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10136Sterile PP Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES-10701Nonsterile MultiDensity Syringe Filters, 0.5(μm), 25(mm), 100 pack
IWT-ES-10702Nonsterile MultiDensity Syringe Filters, 0.7(μm), 25(mm), 100 pack
IWT-ES-10703Nonsterile MultiDensity Syringe Filters, 1.0(μm), 25(mm), 100 pack
IWT-ES-10704Nonsterile MultiDensity Syringe Filters, 1.2(μm), 25(mm), 100 pack
IWT-ES-10705Nonsterile MultiDensity Syringe Filters,1.5(μm), 25(mm), 100 pack
IWT-ES-10706Nonsterile MultiDensity Syringe Filters, 1.6(μm), 25(mm), 100 pack
IWT-ES-10707Nonsterile MultiDensity Syringe Filters, 2.7(μm), 25(mm), 100 pack
IWT-ES-10801Nonsterile A83 NanoScale Syringe Filters, 0.5(μm), 15(mm), 100 pack
IWT-ES-10802Nonsterile A83 NanoScale Syringe Filters, 0.5(μm), 25(mm), 100 pack
IWT-ES-10803Nonsterile A83 NanoScale Syringe Filters, 0.5(μm), 30(mm), 100 pack
IWT-ES-10751High purity CA fibrous protein Syringe Filters, hydrophilic, 1.0(μm), 15(mm), 100 pack
IWT-ES-10752High purity CA fibrous protein Syringe Filters, hydrophilic, 1.0(μm), 25(mm), 100 pack
IWT-ES10400Tri-Layer PP/GF prefilter Nonsterile Nylon Syringe Filters, 0.45(µm),25(mm),100 /pack
IWT-ES10401Tri-Layer PP/GF prefilter Nonsterile Nylon Syringe Filters, 0.22(µm), 25(mm),100 /pack
IWT-ES10405Tri-Layer PP/GF prefilter Nonsterile PVDF Syringe Filters, 0.45(µm),25(mm),100 /pack
IWT-ES10406Tri-Layer PP/GF prefilter Nonsterile PVDF Syringe Filters, 0.22(µm), 25(mm),100 /pack
IWT-ES10410Tri-Layer PP/GF prefilter Nonsterile PTFE Syringe Filters, 0.45(µm),25(mm),100 /pack, hydrophobic
IWT-ES10411Tri-Layer PP/GF prefilter Nonsterile PTFE SyringeFilters, 0.22(µm), 25(mm),100 /pack, hydrophobic
  

Syringe Filter Capabilities

Beyond the extensive product selection found within our standard syringe filter list, we offer OEM capabilities for engineering, molding and insertion of many additional membrane and membrane/pre-filter options. We can work with most of our own membrane and specialty materials as well as convert your supplied product. Please contact us for full engineering capabilities as well as process flow and project management services in this field.

  • Filter insertion in clean room by manual as well as fully automated means.
  • Molding in place, over molding and support structure molding of fragile media.
  • Ultrasonic welding of barrel structure for increased leak / burst resistance.
  • Multi-process mold extensions for inclusion of single or multi-level prefiltration media.
  • Digital variable print capabilities along arc on barrel face for identification purposes.
  • Blister packing for EO and gamma sterilization.
  • Pure virgin PP, verified by HPLC against U/L extractables.

13mm diameter syringe filter:

  • Filter Ø: 13 mm
  • Filtration area: 1.09 mm2
  • Housing material: polypropylene
  • Holdup volume: <20 µl
  • Sample volume: <10 ml
  • Maximum Operating Temperature: 130°C (Housing only, also dependent on membrane)
  • Maximum Operating Pressure: 87 psi (Housing only, also dependent on membrane)
  • Inlet: Luer lock female
  • Outlet: Luer slip male

17mm diameter syringe filter:

  • Filter Ø: 17 mm
  • Filtration area: 1.65 cm2
  • Housing material: polypropylene
  • Holdup volume: <20 µl
  • Sample volume: <20 ml
  • Max. housing pressure: 8 bar
  • Maximum Operating Temperature: 80°C (Housing only, also dependent on membrane)
  • Maximum Operating Pressure: 87 psi (Housing only, also dependent on membrane)
  • Inlet: Luer lock female
  • Outlet: Luer slip male
  • Biological Safety: Filter medium and housing material meet USP XXII Class VI,121 ?

25mm diameter syringe filter:

  • Filter Ø: 25 mm
  • Filtration area: 4.08 cm2
  • Housing material: polypropylene
  • Holdup volume: <100 µl
  • Sample volume: <100 ml
  • Maximum Operating Temperature: 130°C (Housing only, also dependent on membrane)
  • Maximum Operating Pressure: 87 psi (Housing only, also dependent on membrane)
  • Inlet: Luer lock female
  • Outlet: Luer slip male
  • Biological Safety: Filter medium and housing material meet USP XXII Class VI,121 ?

30mm diameter syringe filter:

  • Filtration area: 4.9cm2
  • Housing material: polypropylene
  • Holdup volume: <100 µl
  • Sample volume: <120 ml
  • Max. housing pressure: 8 bar
  • Maximum Operating Temperature: 80°C (Housing only, also dependent on membrane)
  • Maximum Operating Pressure: 87 psi (Housing only, also dependent on membrane)
  • Inlet: Luer lock female
  • Outlet: Luer slip male
  • Biological Safety: Filter medium and housing material meet USP XXII Class VI,121 ?

50mm diameter in-line filter:

  • Housing Polypropylene
  • Connector Inlet/Outlet: 7~13 mm stepped hose barb connection
  • Filtration Area, ft² ≥0.021
  • Maximum Operating Pressure Forward: 3.5 bar @ 23? and 3.0 bar @ 60? for liquid, 3.0 bar @ 23? and 2.5 bar @ 60? for air & gas
  • Sterilization By EO, gamma or autoclave cycle of 30 min at 123?; steam-in-place sterilization not recommended



Manufacturer Part Number/SKU: LEIWT-ES10106-PK

Tags: I. W. Tremont